45 Views

X-Ray Inspection for Semiconductor Package Failure Analysis

Many important semiconductor package defects are completely hidden from optical inspection. A solder ball can contain a void. A bond wire can be broken inside an encapsulated package. A die-attach layer may contain large areas of voiding. A package substrate can contain an open trace, and an advanced package may have a defective microbump buried beneath multiple dies and interconnect layers. Opening the package immediately is not always the best approach. Destructive  preparation can remove evidence, introduce artifacts or make it impossible to determine whether a defect existed before the analysis began. This is where X-ray inspection becomes extremely valuable. X-ray imaging allows failure analysts to examine internal structures of semiconductor devices, packages and electronic assemblies with little or no physical modification of the sample.

 

Typical semiconductor X-ray applications include:

  • Bond-wire inspection
  • Die-attach void analysis
  • BGA and solder-joint inspection
  • Microbump inspection
  • Package substrate analysis
  • Metal bridging
  • Through-hole solder analysis
  • Package cracks
  • Interconnect opens
  • Advanced 2.5D and 3D packaging
  • PCB and board-level failure analysis

 

What Is Semiconductor X-Ray Inspection?

X-ray inspection uses high-energy electromagnetic radiation to create images of structures hidden inside a semiconductor device or electronic package.

In a conventional projection system:

 

X-ray source

Semiconductor device or package

X-rays pass through the sample

Detector records transmitted X-rays

Internal structures become visible

 

Different materials absorb X-rays differently. Dense or high-atomic-number materials generally attenuate the X-ray beam more strongly than lighter materials. This difference creates contrast between structures such as metals, silicon, solder and organic package materials.

 

Why X-Ray Is Useful in Semiconductor Failure Analysis

One of the biggest advantages of X-ray inspection is that it can provide information before the package is destructively opened.

 

Deep penetration

X-rays can penetrate relatively thick semiconductor and package structures, allowing complete packages and circuit boards to be examined internally.

 

Non-destructive inspection

The device normally requires little sample preparation or modification.

This allows X-ray analysis to be performed early in the failure-analysis sequence.

 

No sample charging

Unlike electron-beam analysis, X-ray imaging does not suffer from the electrical charging artifacts that can affect insulating materials during SEM inspection.

 

Internal and surface structures

When combined with computed tomography, X-ray imaging can reconstruct internal structures in three dimensions.

 

Material contrast

Different materials can often be distinguished according to their X-ray attenuation.

These characteristics make X-ray particularly attractive for package failure analysis, where the defect is frequently hidden inside an opaque structure.

 

Where X-Ray Fits in the Failure Analysis Process

A good semiconductor failure-analysis sequence generally moves from the least invasive methods toward progressively more destructive techniques. A typical package investigation might follow:

 

Failure history review

External optical inspection

Electrical verification

X-ray inspection

Scanning Acoustic Microscopy if required

Electrical fault localization

Controlled package opening

SEM / FIB / physical analysis

Root cause

 

Non-destructive investigations should ideally be performed on the as-received device before destructive analysis begins. This preserves a record of the original sample condition and reduces the risk of mistaking preparation damage for the original failure.

 

How Does an X-Ray Inspection System Work?

Most conventional electronic-device X-ray systems use projection imaging. The sample is positioned between the X-ray source and detector. The detector records the transmitted X-ray intensity after the beam has passed through the sample.

The resulting image is effectively a shadow image representing variations in X-ray absorption. Image performance is influenced by factors including:

 

  • X-ray source spot size
  • Geometric magnification
  • Detector pixel size
  • Sample geometry
  • Material composition

 

Geometric Magnification

Unlike an optical microscope, a projection X-ray system can obtain magnification by changing the physical position of the sample. Moving the device closer to the X-ray source increases geometric magnification.

 

A simplified geometry is:

X-ray source → sample → detector

 

If the sample is moved closer to the source while the detector remains farther away, the projected image becomes larger. However, magnification alone does not guarantee greater useful resolution.

The source spot size and detector characteristics also determine how much fine detail can actually be resolved. A highly magnified image is therefore not necessarily a high-resolution image.

 

2D X-Ray Inspection

2D X-ray imaging is one of the most widely used forms of semiconductor package inspection. The device is placed in the beam and a projection image is collected.

 

The sample can often be:

  • Rotated
  • Tilted
  • Moved laterally
  • Viewed at different magnifications

 

This allows the failure analyst to examine the same internal structures from different directions. 2D projection systems can provide relatively fast inspection, making them particularly useful when the approximate defect location is already known.

 

What Can 2D X-Ray Inspection Detect?

 

Die-Attach Voids

X-rays can reveal areas where the die-attach material is absent or nonuniform.

Void size, distribution and overall coverage may often be evaluated.

 

Broken Bond Wires

High-magnification X-ray images can reveal damaged or disconnected bond wires inside encapsulated packages.

This is particularly useful because optical inspection cannot see through the molding compound.

 

Through-Hole Solder Defects

Angled or oblique X-ray imaging can help identify through-hole connections with incomplete soldering or insufficient fill.

 

Missing Solder

X-ray imaging can reveal insufficient or completely absent solder at an interconnect.

 

Metal Bridging

Unexpected conductive material connecting neighboring structures may be visible as an abnormal high-density feature.

 

X-Ray Inspection of Bond Wires

Wire-bond failures are a common application for package X-ray inspection.

 

Possible problems include:

  • Broken wires
  • Missing wires
  • Incorrect wire routing
  • Wire sweep
  • Wire-to-wire contact
  • Wire-to-lead-frame contact
  • Abnormal loop geometry

 

Because the wire is surrounded by package material, these defects may not be visible from outside the device. X-ray provides a way to check bond-wire geometry without decapsulation.

However, X-ray may show that a wire is physically abnormal without determining why the wire failed. Further analysis may still be required to determine whether the mechanism was:

 

  • Mechanical stress
  • Corrosion
  • Bond weakness
  • Electrical overstress
  • Manufacturing damage
  • Another cause

 

X-ray helps locate and document the defect. Root-cause analysis still requires correlation with other evidence.

 

X-Ray Inspection of Die Attach

The die-attach layer provides mechanical attachment and, in many semiconductor products, an important thermal path between the die and package.

 

Voids within this layer may affect:

  • Heat transfer
  • Mechanical support
  • Reliability
  • Thermomechanical stress

 

X-ray can reveal voids because the missing material changes the amount of X-ray attenuation. The result may appear as areas of different contrast underneath the die.

 

X-Ray Inspection of BGA Packages

Ball Grid Array packages are particularly well suited to X-ray inspection because the solder joints are located underneath the component. These joints cannot normally be inspected directly using conventional optical microscopy.

 

X-ray may reveal defects such as:

  • Solder voids
  • Missing solder balls
  • Bridged solder balls
  • Open joints
  • Abnormal solder shape
  • Misalignment
  • Cracks in suitable 3D imaging conditions
  • Interface defects

 

For simple BGA structures, 2D X-ray may provide sufficient information. For complex packages, however, structures from different depths overlap in the same projection. This leads to one of the most important limitations of 2D X-ray.

 

The Problem With Overlapping Structures

A 2D X-ray image compresses a three-dimensional package into a single projection.

 

Consider a complex device containing:

  • BGA solder balls
  • Package traces
  • Microbumps
  • Multiple dies
  • Bonding structures
  • Vias

 

All of these structures may appear on top of one another in the same image. A defect could therefore be hidden behind another high-density feature. In complex multilevel packages, 3D X-ray imaging can separate structures according to depth, making defect interpretation significantly easier.

 

What Is 3D X-Ray Computed Tomography?

Computed Tomography (CT) creates a three-dimensional representation of the internal structure of the sample. Rather than collecting only one projection, the system acquires many X-ray images while the sample is rotated.

 

The basic sequence is:

Acquire X-ray projection

Rotate sample

Acquire another projection

Repeat over many angles

Computer reconstruction

3D dataset

 

The reconstructed data can then be examined in ways that are impossible using conventional 2D imaging.

 

Virtual Cross-Sectioning

One of the most useful features of X-ray CT is virtual cross-sectioning. Once a three-dimensional dataset has been generated, software can display slices through different positions inside the sample.

 

For example:

Complete package

Select depth

View BGA layer

Select another depth

View substrate traces

Select another depth

View die / microbumps

 

No physical cut is required. This provides a major advantage in failure analysis because the analyst can determine where a defect is located before committing to destructive cross-sectioning. In some investigations, virtual cross-sections may provide enough information that a physical cross-section is not required.

 

Example: Open BGA Solder Joint

Consider two neighboring BGA joints inside a complex package. A 3D dataset may reveal that one solder joint is open even though the solder appears normal in a conventional top-down projection.

For example, solder may have wetted the package pad but failed to form a complete interface with the solder ball. Such defects can be difficult to identify reliably in 2D because surrounding structures obscure the interface.

This illustrates one of the strongest applications of 3D X-ray:

determining the actual interface condition between structures rather than simply observing their projected shape.

 

Example: Crack Between a Solder Ball and Via

Virtual cross-sectioning can also expose a crack between a solder ball and an underlying via or interconnect structure. A small defect buried among several other package features may be difficult to separate in a conventional projection.

By examining the reconstructed CT data at the correct depth, the analyst can isolate the suspect interface. This type of capability becomes increasingly important as package structures become more complex.

 

X-Ray Inspection of Advanced Semiconductor Packages

Modern semiconductor packaging increasingly combines many different structures within a single device.

 

Examples include:

  • Flip-chip packages
  • Multi-chip modules
  • Package-on-Package
  • 2.5D packages
  • 3D packages
  • TSV-based structures
  • Microbumps
  • Interposers
  • Embedded components

 

As complexity increases, the distinction between die-level, package-level and board-level failure analysis becomes less clear. Hidden defects in highly integrated packages may be buried beneath multiple material layers and interconnections, making non-destructive localization increasingly important before physical analysis begins.

 

X-Ray for 2.5D and 3D Failure Analysis

3D X-ray microscopy can be especially valuable for advanced packaging because a reconstructed volume can reveal defects deep inside structures that are difficult to access physically.

 

Potential structures include:

  • Interposer traces
  • Microbumps
  • TSV connections
  • Package substrates
  • Stacked dies
  • Multi-level solder structures

 

A useful strategy can therefore be:

Electrical fault identified

Non-destructive X-ray localization

3D dataset generated

Virtual cross-sections identify defect coordinates

Targeted physical analysis only if needed

This can significantly reduce the amount of destructive preparation required.

 

Micro-CT for Semiconductor Failure Analysis

Micro-CT is increasingly useful for complex semiconductor packages. Modern micro-CT workflows can automate:

  • Image acquisition
  • Sample rotation
  • Volume reconstruction
  • Cross-sectional viewing
  • Defect analysis

 

Micro-CT is particularly suited to situations where the package contains multiple overlapping structures that make 2D analysis ambiguous.

 

High-Resolution and Nano-Scale X-Ray Imaging

For smaller structures, higher-resolution X-ray approaches can extend inspection toward features that are difficult to characterize using conventional projection systems. 

 

These methods can be useful for:

  • Microbumps
  • Fine interconnects
  • Advanced packages
  • Small internal defects

 

The trade-off is typically that higher-resolution 3D analysis requires:

  • Smaller Regions of Interest
  • Longer acquisition times
  • More demanding reconstruction
  • More specialized equipment

 

The correct X-ray technique should therefore be selected according to the scale of the suspected defect.

 

2D X-Ray vs. 3D X-Ray CT

X-Ray Technique Main Advantage Typical Use
2D Projection X-Ray Fast inspection and real-time manipulation Bond wires, die attach, simple solder joints, obvious package defects
Oblique 2D X-Ray Helps separate structures by changing viewing angle Through-hole joints, wire bonds, solder structures
Micro-CT Three-dimensional imaging and virtual cross-sections BGA, flip-chip, package substrates, multilevel packages
High-Resolution 3D X-Ray Analysis of smaller internal features Microbumps, advanced packaging and fine interconnect structures

 

The general principle is: Use 2D first when it provides the answer.

 

Move to 3D when overlapping structures or defect complexity prevent reliable interpretation.

 

X-Ray Resolution in Semiconductor Failure Analysis

Resolution is one of the most important considerations when selecting an X-ray technique.

 

For projection systems, important factors include:

  • X-ray focal spot size
  • Geometric magnification
  • Detector pixel size
  • Sample geometry
  • Source-to-sample distance
  • Sample-to-detector distance

 

There is therefore no single X-ray resolution that applies to every semiconductor package. The achievable result depends on the complete imaging geometry.

 

Resolution vs. Field of View

High-resolution imaging often involves a trade-off. To examine a very small package feature in greater detail, the Region of Interest may occupy most of the detector.

This reduces the amount of the overall device visible in one scan. A practical failure-analysis workflow may therefore use:

 

Low magnification

to locate the region

followed by

High magnification

to examine the suspected defect.

 

Resolution vs. Acquisition Time

3D X-ray CT requires many individual projection images. Higher-quality reconstruction may require:

  • More projections
  • Longer exposures
  • Smaller voxels
  • Improved signal-to-noise ratio

 

As a result, high-resolution CT can take substantially longer than a simple 2D inspection. The failure analyst should therefore not automatically select the highest available resolution.

The more useful question is: What resolution is required to answer the failure-analysis question?

 

CAD Overlay With X-Ray Imaging

X-ray data can also be correlated with package or board CAD information.  The X-ray image shows the physical device. The CAD data shows the intended design.

 

When the two are aligned, the analyst can correlate a suspicious feature with: 

  • Pad IDs
  • Package traces
  • Component locations
  • Interconnect positions

 

This can help connect X-ray evidence with electrical-test data and package design information.

 

X-Ray for PCB and Board-Level Failure Analysis

X-ray inspection is also highly valuable at board level. Modern electronic boards may contain:

 

  • BGA packages
  • Embedded components
  • Stacked vias
  • Dense solder joints
  • Package-on-Package devices

 

Optical inspection cannot access many of these structures. Board-level applications may include:

  • BGA solder joints
  • Cracked components
  • Through-hole joints
  • Embedded interconnects
  • Microvias
  • Package-to-board interfaces

 

Using X-Ray With Electrical Failure Analysis

X-ray becomes much more effective when the electrical failure signature is already understood.

 

Open Circuit

Possible X-ray targets include:

  • Broken wire
  • Open solder joint
  • Cracked trace
  • Missing connection

 

Short Circuit

Possible targets include:

  • Solder bridge
  • Metal bridging
  • Foreign conductive material
  • Abnormal interconnect geometry

 

Intermittent Failure

Possible targets include:

  • Cracked solder joint
  • Partially fractured wire
  • Mechanical interface problem

 

The electrical signature should therefore be verified before deciding which internal structures to inspect.

 

Using X-Ray Before Cross-Sectioning

A major practical use of X-ray is to guide subsequent physical cross-sectioning. Suppose CT reveals a crack inside one solder joint. Rather than sectioning the package randomly, the analyst can determine:

  • Which interconnect is defective
  • Approximate defect depth
  • Cross-section orientation
  • Direction of approach

 

The physical cut can then target the actual defect. This reduces the chance that a cross-section will simply miss the failure.

 

X-Ray vs. Scanning Acoustic Microscopy

X-ray and Scanning Acoustic Microscopy (SAM) are both non-destructive package-analysis techniques, but they detect different physical characteristics.

 

X-Ray

Primarily sensitive to:

  • Density
  • Material thickness
  • Geometry
  • High-density structures

 

Particularly useful for:

  • Solder
  • Metals
  • Bond wires
  • Vias
  • Interconnect structures

 

SAM

Primarily detects changes at material interfaces through differences in acoustic properties. Particularly useful for:

  • Delamination
  • Cracks
  • Voids
  • Interface separation

 

The two techniques are therefore complementary. A defect that is difficult to detect with X-ray may be obvious in SAM, and vice versa.

 

X-Ray vs. Optical Microscopy

Optical microscopy is normally the first inspection method because it is:

  • Fast
  • Simple
  • Non-destructive
  • Capable of showing color and surface condition

 

But it can only observe exposed or optically accessible structures. X-ray’s main advantage is its ability to see through opaque package material. A good workflow therefore begins with:

Optical inspection

then

X-ray if hidden structures must be examined.

 

X-Ray vs. SEM

X-ray and SEM address different parts of the investigation.

 

X-Ray

  • Primarily non-destructive
  • Examines internal package structures
  • Can inspect complete packages
  • Useful for locating hidden defects

 

SEM

  • Requires exposed surfaces
  • Provides substantially greater surface detail
  • Useful for physical defect characterization
  • Frequently used after package opening or cross-sectioning

 

A common sequence is:

X-ray locates defect

Cross-section exposes defect

SEM characterizes defect

 

 

X-Ray vs. FIB

Focused Ion Beam is not normally used for broad non-destructive inspection.

 

Instead:

X-ray identifies the buried Region of Interest

 

followed by:

FIB precisely exposes the selected structure

 

This combination can be particularly useful for:

  • Microbumps
  • Vias
  • Small solder defects
  • Advanced package interconnects

 

Common Defects Detected With Semiconductor X-Ray Inspection

Suspected Defect Typical X-Ray Approach What May Be Observed
Die-attach void 2D X-ray Void size, distribution and coverage
Broken bond wire High-magnification 2D X-ray Discontinuity or abnormal wire geometry
Wire sweep 2D / angled X-ray Displacement of wire loops
Missing solder 2D X-ray Lack of expected solder material
Solder bridge 2D X-ray Conductive connection between neighboring joints
BGA open 3D CT Separation at pad / solder-ball interface
Solder void 2D or 3D X-ray Internal low-density region
Package crack 3D CT where suitable Crack through internal package structure
Microbump defect High-resolution 3D X-ray Open, void or abnormal geometry
Substrate interconnect defect 3D CT Open, displacement or bridge
Through-hole defect Angled 2D X-ray Incomplete solder fill or connection

 

Limitations of X-Ray Inspection

X-ray is powerful, but not every semiconductor defect is visible.

 

Limited Contrast Between Similar Materials

If two materials have similar X-ray attenuation, distinguishing their interface can be difficult.

 

Overlapping Structures in 2D

Multiple layers can obscure one another.

3D imaging may be required.

 

Very Small Defects

Some semiconductor-level defects remain below the practical resolution of package-level X-ray systems.

 

Electrical Defects Without Structural Change

A transistor can fail electrically without creating any X-ray-visible physical difference.

 

Interpretation

An unusual image feature does not automatically prove root cause.

The X-ray evidence must be correlated with the electrical failure signature and other analysis.

 

Can X-Ray Damage an IC?

X-ray inspection is generally considered much less invasive than physically opening or cross-sectioning a semiconductor package.

Most package-level X-ray inspections can be performed while preserving the device for subsequent analysis.

However, X-rays are ionizing radiation.

Exposure conditions should therefore be considered when analyzing particularly radiation-sensitive devices.

 

X-Ray Imaging and Failure Analysis Artifacts

One reason to perform X-ray early is that it can document the sample before destructive analysis creates artifacts.

 

Possible artifacts from later preparation can include:

  • Cracks
  • Delamination
  • Solder deformation
  • Wire damage
  • Material smearing

 

If a defect is already visible in the initial X-ray data, the analyst has strong evidence that it existed before destructive sample preparation.

 

This can be extremely important in root-cause investigations.

 

Example Failure Analysis: BGA Open

Consider a semiconductor package with an intermittent open circuit.

 

Step 1 – Electrical Verification

Electrical testing confirms the open.

Step 2 – Optical Inspection

No external abnormality is found.

Step 3 – 2D X-Ray

No obvious defect is visible because the package contains several overlapping interconnect layers.

Step 4 – 3D X-Ray CT

Virtual cross-sections identify separation at one BGA interface.

Step 5 – Physical Cross-Section

The package is sectioned through the exact suspect joint.

Step 6 – SEM

The interface morphology is examined.

Step 7 – Root-Cause Determination

The X-ray, electrical and physical evidence are correlated with assembly history.

 

This illustrates the role of X-ray: Non-destructively locate first, destructively confirm only when required.

 

Example Failure Analysis: Package Short

Consider a device failing with a resistive short between neighboring pins.

 

Electrical Testing

Confirms the short.

2D X-Ray

Inspection reveals unexpected dense material between neighboring interconnect structures.

Additional Fault Localization

Thermal or magnetic-current imaging may further confirm the location.

Cross-Section / SEM

Physical analysis identifies the conductive defect.

 

The final root cause could potentially involve:

  • Solder residue
  • Metal extrusion
  • Foreign material
  • Assembly contamination

 

X-ray can reveal the physical abnormality but must still be combined with material and process evidence.

 

Example Failure Analysis: Cracked Component on PCB

Consider a board showing an electrical short somewhere along a power rail containing many components. Thermal analysis can first narrow the suspected area to one component.

High-magnification X-ray analysis may then reveal a fine crack within that component. The X-ray information can subsequently be used to choose the optimum orientation for destructive cross-sectioning.

Physical analysis can then determine whether the crack and associated damage explain the electrical failure. This illustrates how multiple non-destructive techniques can work together before destructive physical analysis.

 

Why Non-Destructive Analysis Should Come First

Modern semiconductor failure analysis should preserve the sample for as long as practical. This is especially important when only one failed device is available. A useful principle is:

 

Document before destroying.

X-ray can help determine:

  • Whether a package defect exists
  • Where it is located
  • Which structure is involved
  • Whether a cross-section is necessary
  • Where that cross-section should be made

 

This improves the probability of finding the true defect while reducing unnecessary sample damage. 

 

Frequently Asked Questions About Semiconductor X-Ray Inspection

 

What is semiconductor X-ray inspection?

Semiconductor X-ray inspection is a non-destructive technique that uses X-rays to visualize structures hidden inside IC packages, electronic assemblies and circuit boards.

 

What defects can X-ray detect in semiconductor packages?

Typical defects include:

  • Bond-wire problems
  • Die-attach voids
  • Solder voids
  • Missing solder
  • BGA opens
  • Solder bridges
  • Microbump defects
  • Package interconnect problems

 

The exact detectability depends on defect size, material contrast, sample geometry and X-ray system resolution.

 

Is X-ray inspection destructive?

Normally no.

One of its main advantages is that packaged devices can be inspected internally without opening or physically sectioning the package.

 

What is the difference between 2D and 3D X-ray inspection?

2D X-ray creates a projection through the complete device.

3D CT collects projections from many angles and reconstructs the internal structure as a volume.

3D imaging is particularly useful when multiple structures overlap in a conventional projection.

 

What is Micro-CT?

Micro-CT is X-ray computed tomography optimized for microscopic structures.

It is commonly used to inspect electronic packages where three-dimensional separation of internal features is required.

 

What is X-ray virtual cross-sectioning?

Virtual cross-sectioning uses a reconstructed 3D X-ray dataset to display slices through the interior of a package without physically cutting it.

This can help identify the correct location for subsequent destructive analysis.

 

Can X-ray inspect BGA solder joints?

Yes.

BGA inspection is an important X-ray application because the solder joints are hidden beneath the package.

 

Can X-ray detect a broken bond wire?

Yes, provided the wire and defect can be resolved with sufficient contrast and imaging resolution.

 

Can X-ray detect delamination?

Some voids or separations may produce X-ray contrast, but Scanning Acoustic Microscopy is often more sensitive to delamination and small gaps at package interfaces.

 

Can X-ray replace physical cross-sectioning?

Sometimes.

3D X-ray and virtual cross-sectioning can provide enough information to avoid destructive preparation in some investigations.

However, SEM, FIB or materials analysis may still be required when the precise failure mechanism must be established.

 

Does X-ray analysis identify root cause?

Not by itself.

X-ray identifies internal structures and potential physical defects.

Root cause requires correlation with electrical testing, failure history, process information and, where necessary, additional physical or materials analysis.

 

X-Ray as Part of a Complete Semiconductor Failure Analysis

The real value of X-ray inspection is not simply the ability to “see inside” an IC. Its importance comes from where it sits in the analytical sequence.

 

A semiconductor failure-analysis investigation can progressively narrow the problem from:

Complete device

Package

Internal structure

Specific interconnect

Physical defect

Failure mechanism

Root cause

X-ray is particularly effective in the first half of this process because it can identify internal abnormalities while the package remains largely intact.

For straightforward defects, 2D X-ray may provide the answer quickly.

For advanced packages containing many overlapping structures, 3D X-ray CT can provide virtual cross-sections and isolate defects that would be extremely difficult to identify in conventional projections.

As semiconductor packages become increasingly three-dimensional, the value of non-destructive internal imaging also increases.

 

The best failure-analysis strategy is therefore not:

Open the package and look for the defect.

 

It is:

Characterize the electrical failure → inspect non-destructively → localize the defect → then perform targeted physical analysis only where necessary.

 

Need X-Ray Inspection or Semiconductor Failure Analysis Support?

If you have a failed semiconductor package, IC, BGA, WLCSP or advanced package that requires X-ray inspection, AnySilicon can help connect you with semiconductor failure-analysis providers with the appropriate capabilities.

 

Typical services may include:

  • 2D X-ray inspection
  • 3D X-ray CT
  • X-ray microscopy
  • BGA inspection
  • Bond-wire inspection
  • Die-attach void analysis
  • Solder-joint analysis
  • Microbump analysis
  • Package substrate inspection
  • SEM analysis
  • FIB cross-sectioning
  • Scanning Acoustic Microscopy
  • Complete package failure analysis

 

Please use this link.

Logo Image
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.